Toggle switch SS-12D06
Main data
1、RATING:1.5A 125V AC
2、FUNCTION:1P2T
3、TIMING:NO SHORTING
4、ELECTRICAL CHARACTERISTICS:
ITEM TEST CONDITIONS PERFORMANCE
4.1 CONTACT
RESISTANCE
MEASURED AT SMALL CURRENT(100mA OR LESS) 100mΩMAX.
4.2 INSULATION
RESISTANCE
APPLY A VOLTAGE OF 500V DC FOR 1 MIN.
TO FOLLOWING PORTIONS AFTER WHICH MEASUREMENT SHALL BE MADE.
{C}(1)BETWEEN BODY AND TERMINAL
{C}(2)BETWEEN TERMINALS
100MΩMIN
4.3 DIELECTRIC
STRENGTH
AC500V(50-60Hz)FOR 1 MIN TRIP CURRENT:0.5mA BETWEEN TERMINALS.
BETWEEN INDIVIDUAL
TERMINALS AND FRAME
WITHOUT DAMAGETOPARTS ARCING OR BREAKDOWN ETC
5、MECHANICAL CHARACTERISTICS
ITEM TEST CONDITIONS PERFORMANCE
5.1 OPERATING
FORCE
MEASUREMENT SHALL BE MADE ST THE NEAREST POINTF OF THE COMPONENT OR AT THE POINT 3mm FROM THE TIP OF THE ACTUATOU(KNOB0) 300gf±100gf
5.2 TERMINAL
STRENGTH
A STATIC LOAD OF(500gf)SHALL BE APPLIED TO THE TERMINAL FOR 15 SEC,IN ANY DIRECTON MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED WITHOUT LOOSENESS OF ACTUATOU
5.3 DISPLACEMENT
OF ACTUATOR
(KNOB)
A STATIC LOAD OF 10N(1Kgf)SHALL BE APPLIED TO THE TOP OF THE ACTUATOR(KNOB)AND THEN DESPLACEMENT SHALL BE MEASURED TO THE DIRECTION OF THE ARROW THE LEVER SHALL HAVE NO SERIOUS DEFORMATION AND FUNCTION IS NORMALLY
6、ENDURANCE CHARACTERISTICS:
ITEM TEST CONDITIONS PERFORMANCE
6.1 LIFE
TEST
ENDURANCE WITHOUT LOADING:
A SWITCH SHALL BE SUBJECTED TO 10,000 CYCLES AT A SPEED OF 15 TO 18 CYCLES PER MINUTE WITHORT LOADING
(1)CONTACT RESISTANCE 200mΩ MAX
(2)INSULATION RESISTANCE 50MΩ MIN
(3)WITHSTAND VOLTAGE AC 500V,1 MINUTE
(4)OPERATING FORCE ±30%INITIAL VALUE
(5)WITHOUT DAMAGE TO PARTS ARCING OR BREAKDOWN ETC
6.2 SOLDERA-BILITY
TEST
THE TOP OF THE TERMINALS SHALL BE DIPPED 2mm IN THE SOLDER BATH OF 230±5℃ FOR 3±0.5 SECONDS (1) SOLDER WELTING TIME SHALLBE 3 SEC OR LESS
(2) THE AREA OF SOLDERING SHOULD BE OVER 75%
6.3 RESISTANCE TO SOLDERING HEAT TEST
SOLDER BATH METHOD:
SOLDER TEMPERATURE 260±5℃ IMMERSION TIME3±0.5 SEC IMMERSION DEPTH UP TO THE SURFACE OF THE BOARD 1.6mm DIMENSIONS OF COMPONENT HOLES IN THE PRINTED WIRING BOARD SHALL BEING ACCORDANCE WITH THOSE SPECIFIED IN THES SPECIFICATION.
SOLDERING IRON METHOD:
BIT TEMPERATURE 350±10℃ APPLICATION TIME OF SOLDERING IRON3±0.5SEC HOWEVER EXCESSIVE PRESSURE SHALL NOT BE APPLIED TO THE TERMINAL.
WITHORT DEFORMATION OF CASE OR EXCESSIVE LOOSENESS OF TEMINALS ELECTRICAL CHARACTERISTCS SHALL BE SATISFIED.
6.4 COLD TEST THE SWITCH SHALL BE STORED AT A TEMPERATURE OF -25±3℃ FOR48HOURS. THEN THE SWITCH SHALL BE MAINTAINED AT STANDARD ATMOSPHERIC CONDITIONS FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE. THERE SHALL BE NO DEFORMATION OR CRACKS IN MOLDED PART.
6.5 HEAT TEST THE SWITCH SHALL BE STORED ATA TEMPERATURE OF70±2℃ FOR 48 HOURS. THEN THE SWITCH SHALL BE MAINTAINED AT STANDARD ATMOSPHERIC CONDITIONS FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE. THERE SHALL BE NO DEFORMATION OR CRACKS IN MOLDED PART.
6.6 HUMIDITY TEST THE SWITCH SHALL BE STORED ATA TEMPERATURE OF 40±2℃ AND A HUMIFITY OF 90% TO 95% FOR 96 HOURS.THEN THE SWITCH SHALL BE MAINTAINED AT STANDARD ATMOSPHERIC CONDITION FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE.
6.7 STANDARD ATMOSPHERE CONDITIONS UNLESS OTHERWISE SPECIFIED. THE STANDARD RANGE OF ATMOSPHERE CONDITIONS FOR MAKING MEASUREMENTS AND TESTS ARE AS FOLLOWS:
(1)AMBIENT TEMPERATURE:5℃ TO 35℃
(2)RELATIVE HUMIDITY:45% TO 85%
(3)AIT PRESSURE :86Kpa TO 106Kpa
 
6.8 PRACTICAL TEMPERATURE RANCE
AT-16℃—+60℃.